Sensitivity of galvanometer formula
WebWhat is the formula for current sensitivity? The sensitivity (i.e. current sensitivity) of a galvanometer is defined as the angle of deflection per unit current flowing through it. I = k n A B θ where θ is the angle of deflection , N is its turns, A is area, B is magnetic induction & k is the couple per unit twist.
Sensitivity of galvanometer formula
Did you know?
WebThe Ballistic Sensitivity formula is defined as Galvanometer is a special type of galvanometer used to measure the quantity of charge which is passing through any cross-section of a circuit due to transient current or transient voltage is calculated using Ballistic Sensitivity Op = Throw of Galvanometer / Flux charge MMI.To calculate Ballistic … WebNov 5, 2024 · The sensitivity of a galvanometer is higher if the instrument shows larger deflection for a small value of current. Sensitivity is of two …
WebMay 5, 2024 · Voltage Sensitivity of a galvanometer is defined as the deflection produced in the galvanometer when a unit voltage is applied across two terminals. V s = θ V = θ I R = … WebMar 31, 2024 · Sensitivity of a galvanometer is given by the formula as follows, k = I θ = C N B A where N is the number of turns, A is the area of the coil, B is the magnetic field of the magnet and C is the torque per twist in the galvanometer. Complete step-by-step answer:
WebApr 6, 2024 · Voltage sensitivity is defined as deflection caused in the galvanometer when a unit potential difference is applied across it. It is given by- V s = θ V = θ I R ---- (2) Here, V is … WebQ. Current sensitivity of a moving coil galvanometer is 5 div/mA and its voltage sensitivity (angular deflection per unit voltage applied) is 20 div/V. The resistance of the galvanometer is? Q. If the current sensitivity of a galvanometer is doubled, …
WebDec 30, 2024 · The sensitivity of moving coil galvanometer is defined as the ratio of the change in deflection of the galvanometer to the change in the current. Sensitivity = dθ / di. A galvanometer is said to be sensitive if it gives larger deflection for a small current. The current in moving coil galvanometer is given by.
WebDefine the current sensitivity of galvanometer.Write its SI unit. Medium Solution Verified by Toppr Ratio of deflection produced in the galvanometer and the current flowing through it is called current sensitivity.S i= Iθ SI unit of current sensitivity Si … lookin body 120 software downloadWebThe current sensitivity of the galvanometer is the deflection per unit current. Iϕ= kNAB formula Voltage sensitivity voltage sensitivity is the deflection per unit voltage. Vϕ= kVNABI= kRNAB example Deflection obtained in moving coil galvanometer A current of 10 −5 A produces a deflection of 10 0 in a moving coil galvanometer. lookinbody 120 software downloadWebSensitivity of Wheatstone bridge. The sensitivity of a Wheatstone bridge is defined as the deflection in the galvanometer per unit current. In the unbalanced condition of the bridge, when current flows, it causes the pointer of galvanometer to get deflected. Thus, the deflection rate is the function of sensitivity. lookin body softwareWebThe voltage sensitivity of a galvanometer is defined as the deflection per unit voltage of the galvanometer The Voltage Sensitivity determines the amount of angular deflection when … lookinbody mexicoWebOct 25, 2024 · 1/T = 1/T0 + 1/β ln { (RA/R0) ( { [ERB – ΔV (RA + RB)]/ [ERA – ΔV (RA + RB)]})} Considering R A = R B = R C 1/T = 1/T0 + 1/β ln { (RB/R0) [E – 2ΔV]/ [E + 2ΔV]} So, with the above formula temperature can be measured using the Wheatstone bridge. lookin body 120 softwareWebOct 8, 2016 · The bridge sensitivity is defined as the deflection of the galvanometer per unit fractional change in unknown resistance. Sensitivity of Wheatstone bridge, From the above equation, it is clear that the … hops8WebDec 30, 2024 · The sensitivity of the tangent galvanometer is defined as the ratio of the change in deflection of the galvanometer to the current producing this deflection. Sensitivity = dθ / di A galvanometer is said to be sensitive if it gives larger deflection for a small current. Thus the sensitivity of tangent galvanometer can be increased by lookinbody software